What was found
MAIN CABIN FLOOR SUPPORT CHANNEL BETWEEN BS 947.5 & 967 IS CORRODED ON THE UPPER SURFACE AT APPROX RBL50. REMOVED, REPLACED AND INSTALLED NEW FLOOR SUPPORT IAW SRM 51-40-02-0G-0 AND DWG 147A5760, REV -. 194
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FLOOR SUPPORT CHANNEL BETWEEN BS 947.5 & 967 IS CORRODED ON THE UPPER SURFACE AT APPROX RBL50. REMOVED, REPLACED AND INSTALLED NEW FLOOR SUPPORT IAW SRM 51-40-02-0G-0 AND DWG 147A5760, REV -. 194