What was found
FOUND TEE ANGLE AT FWD SIDE OF STA 947.5 AND WL208.1 WITH OUT OF ROUND HOLES. REMOVED AND REPLACED TEE ANGLE AT FLOOR STRUCTURE ON FRAME 947.5 WL 208.1 IAW SRM 51-40-02-0G-0 AND DWG 147A0000 REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND TEE ANGLE AT FWD SIDE OF STA 947.5 AND WL208.1 WITH OUT OF ROUND HOLES. REMOVED AND REPLACED TEE ANGLE AT FLOOR STRUCTURE ON FRAME 947.5 WL 208.1 IAW SRM 51-40-02-0G-0 AND DWG 147A0000 REV-.