As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCH PROCEDURE - ROW 18 FLOOR PROX EMERGENCY LIGHT INOP LIGHT ASSY REPLACED NO HELP. FOUND BROKEN BLACK WIRE IN FLOOR HARNESS. PERFORMED SPLICE REPAIR REF SWPM 20-30-12. OPS CHECL GOOD REF AMM 33-51-00-715-039, REF WDM 33-51-14-3PARTS USED: 29-3326-3-0013,QTY :1