What was found
CRACK FOUND AT FWD GALLEYDOOR STUB FRAME INTERNAL, 1" ABOVE SEAL DEPRESSOR. CRACK LENGTH : 0.787" REF AAR N/R 100027859. REMOVED AND REPLACED R1 DOOR CUTOUT FWD UPPER STUB FRAME PER SRM 51-40-02-0G-0 AND DWG # 141A8370.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK FOUND AT FWD GALLEYDOOR STUB FRAME INTERNAL, 1" ABOVE SEAL DEPRESSOR. CRACK LENGTH : 0.787" REF AAR N/R 100027859. REMOVED AND REPLACED R1 DOOR CUTOUT FWD UPPER STUB FRAME PER SRM 51-40-02-0G-0 AND DWG # 141A8370.