What was found
EMERGENCY LIGHTS - OPERATIONAL CHECK EMERGENCY LIGHTS OPERATIONAL CHECK - FLOOR PROXIMITY LIGHT AT SEAT 26C INOP REPLACED WITH SERVICEABLE WHITE PROXIMITY FLOOR LIGHT, NO HELP. PUT ORIGINAL LIGHT BACK ON. SUSPECTED SEAT HARNESS NIS AT LAS REQUESTING DEFERRAL ALL LIGHTS OPERATE PER DDP MEL33160 TOMC APPROVED IAW MEL 3319E DDP C/W PLACARD INSTALLED RELAMPED FLOOR PROXIMITY LIGHT LAMP REF AMM 33-51-11-960-801. OPS CHECK GOOD AT THIS TIME. MEL PLACARD REMOVED.