As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION: CABIN AFT WET AREA FLOORBEAM STA 947 BETWEEN LBL 8 AND RBL 11 FOUND MULTIPLE CORROSION SPOTS. ACCOMPLISHED PERMANENT REPAIR AT FLOORBEAM STA 947.5 BETWEEN LBL 59 AND RBL 59 PER ESR-WI 10-15187 AND ECRA 5370-01244 NO DIP REQUIRED.