What was found
E/E BAY RT UPPER CHORD ON INTERCOASTAL WEB FOUND GOUGED ON OUTER RADIUS. REMOVED FASTENERS FROM RT E&E DOOR UPPER CHORD OF INTERCOSTAL WEB IAW SRM 51-40-02, ACCOMPLISHED NDT PART 6-51-00-00 NR 16. NO DEFECTS NOTED. PICKED UP AND DRILLED HOLES IN NEW WEB PLATE IAW SRM 51-40-02. PICKED UP AND DRILLED HOLES IN UPPER CHORD AND TRIMMED EDGES REF DWG 141A8512, 141A8512 SHEET 3. TREATED & PRIMED REF AMM 51-21-41 AND AMM 51-21-72. TRIMMED EDGES REF DWG 141A8512, 141A8512 SHEET 3. TREATED & PRIMED IAW AMM 51-21-41 AND AMM 51-21-72. INSTALLED UPPER CHORD OF RIGHT INTERCOSTAL OF ELECTRIC BAY ACCESS IAW SRM 51-40-02 AND DWG 141A8512 SHEET 3.