What was found
LOWER AFT CORNER OF L1 DOOR DAMAGED.REMOVED DAMAGE REF SRM 51-27-11. PERFORMED DOOR SKIN CUT OUT PER STEP 1 OF AVO 17658. REQUESTING INSPECTION OF TRIMMED EDGE PER STEP 2 OF AVO 17658. ACP DISPOSITION 2 ON AVO 17658 NO CRACKS INDICATED REF NTM PT6 51-10-08. COMPLETED DVI OF INTERNAL STRUCTURE PER STEP 3 OF AVO 17658 WITH NO FURTHER FINDINGS. SUBMITTING COMPLETION OF AVO TO ESC. REMOVED CORNER SEAL IAW STEP 4 OF AVO 17658 REV A , REQUESTING INSP TO PERFORM ROTOTEST INSP OF OPEN HOLESAND DVI CHECK PER STEP 5 REMOVED CORNER SEAL IAW STEP 4 OF AVO 17658 REV A , REQUESTING INSP TO PERFORM ROTOTEST INSP OF OPEN HOLES AND DVI CHECK PER STEP 5 COMPLIED WITH STEP 5 OF AVO17658 REV A REF NTM 51-10-01-250-801-A-01 (HFEC). NO DEFECTS NOTED, OK TO CONTINUE COMPLIED W STEP 6 OF AVO 17658 REV B . COMPLIED WITH STEPS 7 -9 , REF AVO 17658 REV B FABRICATED PARTS , DRILLED , DEBURRED , CHAMFER ETC,, EXCLUDING COUNTERSINKING REPAIR DOUBLER AND BACK COUNTERSINKING CHANNEL FOR DOUBLE FLUSH RIVET INSTALLATION.