What was found
CORROSION IN E&E AT ANTENNA CUTOUT BL0 JUST AFT OF DOOR CUTOUT. ACCOMPLISHED INSTALLATION OF NEW CHANNEL AND TIE BRACKET AT MAIN E&E COMPARTMENT BETWEEN BS 351.2 - 360, BL 0 IAW SRM 51-40-02-0G-0, DWG 141A3502 AND DWG 141A1160.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION IN E&E AT ANTENNA CUTOUT BL0 JUST AFT OF DOOR CUTOUT. ACCOMPLISHED INSTALLATION OF NEW CHANNEL AND TIE BRACKET AT MAIN E&E COMPARTMENT BETWEEN BS 351.2 - 360, BL 0 IAW SRM 51-40-02-0G-0, DWG 141A3502 AND DWG 141A1160.