What was found
BRAKE 3 TEMP SENSOR ROSE TO 995C AND CAUSED HOT BRK ECAM IN FLT BRIEFED INBOUD CREW, STATED 5 MILES OUT NR 3 BRAKE TEMP SENSOR READS 900 PLUS C, AFTER LANDING TEMP SENSOR READ NORMAL IN THE GREEN RANGE, FIRE DEPT MET PLANE & INSPECTED FOR FIRE & GLOWING BRAKE, FOUND NOTHING OUT OF THE NORMAL, PERFORMED INSPECTION AFTER BRAKE EMERGENCY APPLICATION OR OVERHEAT REF AMM 05-51-16, FOUND NO SIGN OF FIRE, NO BURN MARKS AND NUMBER 4 BRAKE SENSOR WAS READING NORMAL MEANING NO FIRE SINCE THE HEAT WOULD TRANSFER TO SISTER BRAKE, BOTH 3&4 TIRE FUSE PLUGS INTACT PERFORMED AN OPERATIONAL TEST OF THE NORMAL BRAKING SYSTEM REF AMM 32-42-00-710-001-A AND OP TEST OF THE ALTERNATE BRAKING SYSTEM REF AMM 32-43-00-710-001-A BOTH TEST PASS PERFORMED MEL MAINTENANCE TASK, PULLED AND COLLARED BRK TEMP DET UNIT, REMOVED AND REPLACED NO. 3 BRAKE TEMP SENSOR REF AMM 32-47-15-400-001-A, OPS CHECK GOOD.