What was found
CORROSION AT STRINGER 25L BTWN BS 360 & 380. ACCOMPLISHED INSTALLATION REPAIR IAW SRM 53-00-03-2R-1, DWG 143A3230 AND ESR 2-15301.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AT STRINGER 25L BTWN BS 360 & 380. ACCOMPLISHED INSTALLATION REPAIR IAW SRM 53-00-03-2R-1, DWG 143A3230 AND ESR 2-15301.