What was found
LEFT OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE AT 20FED, 21 FED - RH SIDE. R & R EMERGENCY LIGHT POWER SUPPLY AND BATTERY (M1695). OPS CHECKED GOOD IAW AMM 33-51-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE AT 20FED, 21 FED - RH SIDE. R & R EMERGENCY LIGHT POWER SUPPLY AND BATTERY (M1695). OPS CHECKED GOOD IAW AMM 33-51-06.