What was found
(SDR) LH VERTICAL STAB FIXED SKIN JUST BELOW APPROX FFS 119.467 HAS 1EA DENT. WC: 16068 SFR CW WSHAW ACCOMPLISHED REPAIR IAW SRM 51-70-10-2R-2 VIA PN 04-009-004 BATC H 4464640, RESTORED FINISH IAW SRM 51-21-14-370-803 & SRM 51-21- 15-370-801 PER SRM 55-30-01-2R-5 CLASS B REPAIR, INSPECTION REQU IRED EVERY 24 MONTHS OR 3500 FLIGHT CYCLES. ACCOMPLISHED REPAIR OF LT VERTICAL STAB FIXED SKIN IAW SRM 51-70-10-2R-2 CLASS B REPAIR INSPECTION REQUIRED EVERY 24 MONTHS OR 3500 FLIGHT CYCLES.