What was found
FWD CARGO DOOR, UPPER FORMED FRAME WITH CRACK ON UPPER CHORD AT BS 477. PERFORMED THE REPAIR TO THE UPPER FRAME IAW ECRA 5230-02326, .THE REPAIR ACCOMPLISHED IN PART 1 IS A CATEGORY B REPAIR REQUIRING REPETITIVE INSPECTION REQUIRMENTS (RIR) STATED IN PART 2. PERFORMED THE REPAIR TO THE UPPER FRAME P/N 143A6115-5 IAW ECRA 5230-02326. THE REPAIR ACCOMPLISHED IN PART 1 IS A CATEGORY B REPAIR REQUIRING REPETITIVE INSPECTION REQUIRMENTS (RIR) STATED IN PART 2. REF: DIP L/P FOR INSPECTION IS 9581704 AND DIP L/P TO CONTACT ENGINNEERING IS L/P 9581866 ESFR# 3940 HAS BEEN CREATED. ALL FUTURE WORK TO BE PERFORMED PER THE LATEST REVISION OF ECRA 5230-02326 AS STATED BY DIP L/P 9581704 & PLANNING DIP L/P 9581866. ESFR# 3940 NOTED BY MAINTENANCE, ALL FUTURE WORK TO BE PERFORMED PER THE LATEST REVISION OF ECRA 5230-02326 AS STATED BY DIP L/P 9581704 & PLANNING DIP L/P 9581866.