What was found
RIGHT PACK UNABLE TO SAFE WORKING TEMP IN THE CABIN UNABLE TO CO NTROL TEMP DIVERSION PERFORMED ZONE TEMP CONTROLLER, AND LEFT AND RIGHT PACK CONTROLLER BITE TEST AND NO FAULTS FOUND AT THIS TIME. REF FIM 21-51 TASK 803. PERFORMED VISUAL INSPECTION ON THE RIGHT PACK AND WAS FOUND THE SUPPLY DUCT DETTACHED FROM THE INLET. RE-ATTACHED RIGHT PACK SUPLY DUCT. OPS CHECK AND LEAK CHECK GOOD AT THIS TIME. REF AMM 21-51-03/401