What was found
REF LOG PAGE #9623921 NEED TO COMPLY WITH AVO 17872. STEPS 1-6 WERE ACCOMPLISHED BY DAYSHIFT SHEETMETAL SEE PARENT LOG PAGE FOR SIGNOFF. STEP 7 THRU 10 REQUIRE HFEC INSPECTION. REF. AVO 17872, STEP 7 HFEC ONLY ACP. REF. 757 NDT PT6, 51-00-19. NO DEFECTS NOTED ON FUSELAGE SKIN TRIM.STEP 8 HFEC ACP REF. 757 NDT PT6, 51-00-19, NO DEFECTS NOTED WITHIN 2" INCH RADIUS OF THE FUSELAGE SKIN TRIM. UPDATE - REF. AVO 17872 STEPS 9 & 10, ACP. HFEC OF ALL FASTENER HOLES REF. 757 NDT PT6, 51-00-16 & HFEC OF ALL COUNTERSUNK HOLES IAW NDT PT6, 53-30-03. NO DEFECTS NOTED AT THIS TIME. MEASUREMENTS ARE IN INCHES; CUT WAS PERFORMED PREVIOUSLY CORRECTION: MEASUREMENTS ARE IN INCHES COMPLETED REMAINING STEPS OF AVO 17872 COMPLETED REPAIR REF ECRA 5330-07797. REFER TO LOG PAGES 9649998, 9649954, 9649951, 9649919 AND 9649680 FOR WORK PERFORMED. LOG PAGE 9662710 COMPLETED WORK COMPLETED REF ECRA 5330-07797 RII VERIFIED COMPLETION OF WORK AND SDR/SFR REPORTING C/W