What was found
E&E COMPARTMENT DOOR CUTOUT LT INTERCOSTAL WEB UPPER AREA AND FASTENER HAS DEEP SCRATCHES. REMOVED, FABRICATED AND REPLACED NEW WEB AT E&E DOOR CUTOUT IAW SRM 53-10-15-1A-3, 51-40-02-0G-0, 53-10-15-0I-3, 51-40-05-0G-0, 51-20-01-0G-0, 51-40-04-0G-0, AMM 20-60-07-910-801, 51-21-72-370-804, SOPM 20-30-03, & DWG 141A8512 REV A.