What was found
EMERGENCY LIGHTS, OPS TEST WITH THE TEST SWITCH PROCEDURE, EMERGENCY EXIT IDENTIFIERS AT R1 DOOR, R2 DOOR AFT, RT AFT OVERWING EXIT NEED REPLACED THE LAMPS. REPLACED 1R DOOR LIGHT ASSY L629 DUE TO ENGLISH LETTERING ILLEGIBLE IAW AMM 33-51-10-402-047 AND RELAMPED THE OTHER IDENTIFIER SIGNS AS REQUIRED IAW AMM 33-51-10-962-040, OP CHKD GOOD.