What was found
CRACK FOUND AT R1 FWD GALLEY DOOR STUB FRAME JOGGLE AREA. CRACK LENGTH, 0.75". REF AAR N/R 100059794. REMOVED AND REPLACED R1 DOOR STUB FRAME IAW SRM 51-40-02-0G-0 AND DRAWING 141A8370 SHEET 9, 10, 11, AND DRAWING 141A8380 SHEET 15.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK FOUND AT R1 FWD GALLEY DOOR STUB FRAME JOGGLE AREA. CRACK LENGTH, 0.75". REF AAR N/R 100059794. REMOVED AND REPLACED R1 DOOR STUB FRAME IAW SRM 51-40-02-0G-0 AND DRAWING 141A8370 SHEET 9, 10, 11, AND DRAWING 141A8380 SHEET 15.