As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SECURED WIRES AND COVER FOR EMERGENCY EXIT AISLE LIGHTS AT SEATS 31ABC & 34ABC, IAW AMM 33-51-11. TROUBLESHOOT AND FOUND BUMPER-ENDBAY BUMPER TO HOLD AISLE PATCH LIGHTING HOUSING DAMAGED. INSTALLED NEW SERVICEABLE BUMPER-ENDBAY AND ATTACHED (AISLE) FLOOR PROXIMITY EMERGENCY LIGHT HOUSING REF. CMM 25-22-59. ALL EMERGENCY LIGHT TEST PASSED, OK FOR SERVICE. REF. AMM 33-51-11.