What was found
EXTERNAL FUSELAGE, APU INLET CUTOUT EXTERNAL, HAS EVIDENCE OS CORROSION AT BS 1825, S6R AND BY BS 1787, S3R. PERFORMED REPAIR AT APU INLET CUTOUT STA 1825 IAW SRM 5 3-80-15-2R-1, REPLACED FWD STRAP AT BS 1787 BTW S3-6R, 2 EA SUPPORT ANGLES BTW BS 1825 - 1787, STR 3R & STR 6R, BRACKETS IAW SRM 51-40-02 OG-0, AND DWG 148N3105. RESTORED SURFACE PROTECTION IAW AMM 51-21-15-370-801.