What was found
AFTER PHASE II INSPECTION FOUND LIGHTNING STRIKE ON FASTENER BTW STA 197 AND 8.3 INCHES BELOW OF STRINGER 17R. PERFORMED REPAIR IAW SRM 53-00-01-2R-41 THIS REPAIR IS A CATEGORY A REPAIR AND NOT REQUIRE REPETITIVE INSPECTIONS STEP 2.A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER PHASE II INSPECTION FOUND LIGHTNING STRIKE ON FASTENER BTW STA 197 AND 8.3 INCHES BELOW OF STRINGER 17R. PERFORMED REPAIR IAW SRM 53-00-01-2R-41 THIS REPAIR IS A CATEGORY A REPAIR AND NOT REQUIRE REPETITIVE INSPECTIONS STEP 2.A.