What was found
RAMP REPORTED AFT CARGO BIN THRESHOLD HAS A DENT. DENT IS LOCATED AT CENTER BULLNOSE MEASURES 1.5" W, Y=.150" W/Y=10 & IS OUT OF LIMITS IAW SRM 53-60-15-1A-1, FIG 103, DETAIL H. PERFORMED INTERIM REPAIR IAW ECRA 5310-04013, REV. J. INSPECTED INTERIM REPAIR PER ECRA 5310-04013, OK TO CONTINUE. REINSPECTED TEMP REPAIR AND REAPLIED SPEED TAPE AS NEEDED ISW ERCA 5310-04013. OK TO CONTINUE.