What was found
FLOOR SUPPORT BETWEEN BS 947 & BS 967, RBL 24.75, FOUND TO BE CORRODED. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, AND DWG 147A5650, REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT BETWEEN BS 947 & BS 967, RBL 24.75, FOUND TO BE CORRODED. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, AND DWG 147A5650, REV A.