What was found
ACFT DIVERTED TO CUN FROM RTB DUE ENG 1 BIRD STRIKE. ENG 1 PRELIMINARY INSPECT 2 AFT ACOUSTIC PANELS REPLACED IAW AMM 72-21-08/401 AND 5 OGV PLATFORMS REPLACED IAW AMM 72-21-09/401, ALL OK. FAN BLADE 9. R & R IAW AMM 72-22-02-960-802-G00, OPS CHKD IAW AMM 71-00-00-720-803-G00, ALL OK. FAN BLADE NR 11 R & R IAW AMM 72-22-02-960-802-G00, OPS CHKD WITHIN LIMITS IAW AMM 71-00-00-720-803-G00, ALL OK. FAN BLADES NR 9, 10, 11 R & R IAW AMM 72-22-02-960-802-G00, OPS ENG NR 1 FAN BLADE PLATFORM NR 9 REPLACED IAW AMM 72-22-03/401.