What was found
ALERTING {52-71003} PSEU AFT ENTRY DOOR SWITCH SENSOR IS TARGET FAR IN AIR, FAULTING 5 OF 10 LEGS. AS PRECAUTION. CARRIED BY ELB PERFORMED FIM 52-10, TASK 802, FOUND SENSOR TARGET FOR AFT ENTRY IN MARG POSITION, ADJUSTED THE SENSOR IAW AMM 52-71-11. OPS CHKD GOOD, TARGET WITHIN LIMITS.