As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
(SUPPORT TASK) AFTER PHASE II INSPECTION FOUND LIGHTNING STRIKE ON FASTENER BTW STA 235.8 AND 12" ABOVE OF EXTERNAL POWER CUTOUT. (REF AAR NR 1000084273).PERFORMED REPAIR LIGHTNING STRIKE ON FASTENER BTW STA 235.8 AND 12" ABOVE OF EXTERNAL POWER CUTOUT, THIS REPAIR IS A CATEGORY B REPAIR INSPECTION REQUIREMENTS IAW B737-900ER SRM 53-00-01-2R-41 STEP 6 TABLE 203.