What was found
LEFT WING, NR 2 SLAT HAS A DENT ON THE UPPER SURFACE T/E WEDGE. EVALUATED 1EA DENT ON NR 2 SLAT T/E WEDGE IN UPPER SURFACE IN ZONE 3. DENT MEASURES 30.4" FROM I/B EDGE AND 4.5" FROM T/E W= 1.1", Y= .021" W/Y=47. AFTER FURTHER EVALUATION DENT FOUND TO BE WITHIN ALLOWABLE LIMITS. NO CRACK, CREASE, GOUGE, OR DELAMINATION NOTED IAW SRM 57-42-01-1A-1.