Service difficulty report · Warning Message · Boeing 78710

Difficulty date
August 27, 2026
Submitted
August 31, 2026
Operation
Air carrier
Aircraft
N12005
Make and model
Boeing 78710
Aircraft serial
40937
Aircraft time
32,122 hours, 4,270 cycles
Part
Warning Message
Condition
False Activation
Location
Rt Engine
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ENG EEC C1 RT ENGINE CONTROL IS IN A TIME LIMITED DISPATCH CONDITION. ENGINE CONTROL SYSTEM OPERATING WITH REDUCED REDUNDANCY. DB ELECTRONIC ENGINE CONTROL CHANNEL-A (RIGHT ENG) UPON ARRIVAL FOUND MAINT MESSAGE 73-31212. STATUS MESSAGE ACTIVE BUT CORRELATED MESSAGE SHOWS NOT ACTIVE AT THIS TIME. IAW FIM DMC-B787-A-G73-10-F1-60A-421A-A FOR FURTHER TS. DURING INITIAL TROUBLESHOOTING, EEC MAINT SWITCH WAS ENABLED AND MX. 73-31212 MESSAGE 73-11232 SHOWED NO EXISTING FAULTS FOUND, CHECKED INBOUND FLIGHT DECK EFFECTS & FOUND FAULTS 73-11232 AND 73-31212 IAW FIM DMC-B787-A-G73-10-F1-12A-421A-A, SET RT EEC TO TEST MODE, FAULT 73-11232 SHOWS ACTIVE, NEXT TASK IS TO ACCOMPLISH STEP B. FAULT ISOLATION PROCEDURE. IAW FIM B787-A-G73-10-F1-12A-421A-A, CHECKED CONNECTOR DM7321025P134. FOUND IN GOOD CONDITION, CHECKED RESISTANCES OF FUEL SPLIT VALVE, ALL WITHIN RANGE. CHECKED CONNECTOR DM7321003P7, NO FAULTS NOTED. CHECKED CONTINUITY BETWEEN CONNECTOR DM7321025P134 AND DM7321003P7 ALL WIRE CHECKS GOOD. ACCOMPLISHED GVI OF HARNESS WITH NO ANOMOLIES NOTED. WITH EEC TEST ENGINE FAULT RETURNS. NEXT STEP IN FIM IS TO ACCOMPLISH ENGINE TEST 13. RAN TEST 13 ON RIGHT ENGINE, TEST PASSED AND MSG CLEARED. REF AMM DMC-B787-A-G71-00-00-42B-320A-A.

More about the Boeing 787-10