What was found
CRACK FOUND AT VERTICAL PRESSURE WEB AT LBL 40.00 - LBL45.64. COMPLETED INSTALLATION OF ALL FASTENER ON REPAIR AREA IAW SRM 57-10-10-2R PARAGRAPH 5.L. AND 51-40-02-0G-0 PARAGRAPH 8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK FOUND AT VERTICAL PRESSURE WEB AT LBL 40.00 - LBL45.64. COMPLETED INSTALLATION OF ALL FASTENER ON REPAIR AREA IAW SRM 57-10-10-2R PARAGRAPH 5.L. AND 51-40-02-0G-0 PARAGRAPH 8.