What was found
ON WALK AROUND FOUND DENT FWD OF EXT POWER DOOR.DENT IS IN SECTION 41, BS 276. DENT MEASURES 1.5INCH IN LENGTH, .5INCH WIDTH & .040 INCH DEEP. L/Y IS 33.33 ACP,D HFEC INSP NO CRACKS IAW NTM 51-00-00-23, PART 6. SKIN IS DENTED IN 0.105 IN. WITH .002 MATERIAL LOSS. REWORKED & BLENED DAMAGE AREA. L=3.2 W=3.0 Y=.095 L/Y =31 WITH IN LIMITS IAW SRM 53-00-01. MATERIAL LOSS ACP 777 UT (4) 51-00-10 PROCEDURE 1. ACCOMP HFEC(6) 51-00-02 PROCEDURE 2. NO CRACKS AT GOUGE BLENDOUT. CUT OUT EXISITING DAMAGED & EXISITING FASTERNERS READY TO BE NDT & SRM 53-00-01-2R-7 ACP HFEC (6) 51-00-01 PROCEDURE NR 2 NO CRACKS AT CUTOUT AND DOUBLER AREA. ACCOMP HFEC OPEN HOLE (6)51-00-02 PROCEDURE NR 2 ON EXISTING FASTNER HOLES. NO CRACKS. ACP DVI ON INTERNAL AND EXTERNAL STRUCTURE NO DAMAGE. PILOT DRILLED & SHAPED DOUBLER IAW SRM 53-00-01-2R-7. MANUFACTURED REPAIR DOUBLER, DRILLED REPAIR FASTENER HOLES TO 0.250 INCH, TRIM REPAIR DOUBLER AND MADE FILLER IAW SRM 53-00-01-2R-7. INSTALLED COUNTERSINK REPAIR WASHERS IAW SRM 53-00-01-2R-7, CHAMFERED DOUBLER, FINAL SIZE EXISTING FASTENERS TO -7 OR .2187. COUNTERSUNK ONLY .25 HOLES. STILL NEED TO COUNTERSINK REMAINING HOLES. REF. SRM 53-00-01-2R-7. FINISHED COUNTERS IN VERIFIED WORK COMPLETED , IAW SRM 53-00-01-2R-7 AND ALSO VERIFIED SDR COMPLETED