What was found
NORMAL START ON NUMBER 1 ENGINE. REJECTED TAKEOFF APPROX 60 KNOTS DUE TO NR 1 EGT READING 162 DEGREES. OTHERWISE NORMAL ENGINE INSTRUMENTS AND ACCELERATION NO SWERVING. ADDED FADEC 1B TEST RESUT PICTURE REF TSM 77-20-00-810-801-B, PERFORMED ENG 1 ECTRICAL CABLES, WIRE HARNESS VISUAL INSPECTION REFERENCE AMM TASK 71-50-00-210-010-A. NO DAMAGE, CUTS FOUND THIS TIME. FOUND SHORT TO GROUND ON HARNESS FROM 4007VC TO THE THERMOCOUPLES (DISCONNECTED) REF TSM 77-20-00-810-801-B AND AWM 71-51-08. NEEDS NEW HARNESS. REMOVED AND REPLACED ENG 1 EGT HARNESS IRW AMM 77-21-43. PERFORMED FADEC OPS CHECK IRW AMM TASK 73-22-00-710-040-A. VERIFIED ENG 1 TEMP APPEARS ON ECAM. LEAK CHECK STILL REQUIRED REFER TO LP 3393501 FOR IDLE RUN.