What was found
TWO CRACK SIGNALS NOTED AT HORIZONTAL STAB, LT SIDE HSS 157.10, INBD SIDE. FIRST CRACK L=0.375 INCH LOCATED TO 9.375 INCH FWD FROM AFT SPAR, SECOND CRACK L=0.250INCH LOCATED TO 16.500 INCH FWD FROM AFT SPAR. REPAIRED THE DAMAGE IAW SRM 55-10-01-2R -11,