What was found
STRIKER PLATE FOR FWD RT LATCH ON ECS DOOR 192CR, MISSING. AFTER CLEANING DAMAGE & FINDING IT OUT OF ALLOWABLE DAMAGE LINITS. REMOVED DAMAGE IAW 57-10-13. PERFORMED HFEC IAW NDT PART 6, 51-00-00 PROCEDURE 23, AND NDT PART 6, 51-00-00 PROCEDURE 16. NO DEFCTS NOTED, OK TO CONTINUE. PERFORMED INSURANCE CUT IAW SRM 57-10-13-2R-3, FABRICATED FILLER PART IAW SRM 57-10-13-2R-3 REQUEST MATERIAL VERIFICATION FROM PREVIOUS ENTRIES.