What was found
AFTER NDT INSPECTION ON FRAME 727E UPPER HOLE, FOUND A CRACK . EVALUATED DENT ON VERTICAL LEADING EDGE, FOUND TO BE WITHIN LIMITS IAW SRM 55-30-01-1A-1, PAR. 4.A, TABLE 101. PERFORMED DENT REWORK. PERFORMED NDT, NO CRACK SIGNAL NOTED, AND APPLIED ALODINE IAW SRM 55-30-01-1A-1 PAR. 5. PERFORMED REPAIR ON HOLE AT FRAME 727E, ALL WORK ACCOMPLISHED IAW EO 260465 REV P1, EO 260465 REV P2, EO 260465, REV IR, & EC5360-02205. CLASSIFIED AS A MAJOR REPAIR.