What was found
RIGHT WINDSHIELD FRAME CONTINUITY FITTING AREA ROTO TEST INSPECTIO N FOUND CRACK INDICATION IN MOST I/B HOLE GEN BY V929087 ON AAR LCQ NR 9298821/26821 UP DATED EFSR REPAIRED R/H WINDSHIELD FRAME MOSL I/B FASTENER HOLE IAW A319 EC RA NO.5311-03421 OVERSIZE AND BUSHING INSTALL REPAIR, THE REPAIR ACCOMPLISHED IS A CAL B REPAIR