What was found
DURING THERMOGRAPHY INSPECTION OF OUTBOARD AILERON LH WAS FOUND WATER INGRESS INDICATION. PICTURES ATTACHED. AFTER THERMOGRAPHY INSPECTION WAS FOUND WATER INGRESSION ON LOWER SKIN. DAMAGED AREA WAS REMOVED & REPAIRED FOLLOWING SRM .DONE NEW INSPECTION ON REPAIRED AREA AND DONE REWORKED MOMENT.REF EC/RA 5760-01159 SRM 51-70-05-0G-0 NDT PART9 . 51-00-01 NDT 51-01-01 NDT 51-05-01 . PERFORMED BALANCE PROCEDURE AS REQUIRED PER SRM 51-60-01-0G-0.