What was found
FRAME 68, STR 8R, ABOVE TOP FASTENER IN WEB HORIZONTAL CRACK ALONG RADIUS APPROX .400 LONG IAW LCQ N/R 9292113/40113. REPAIRED AFT CABIN RT FRAME 68, STR 8R UPPER FRAME IAW SRM 53-41-12-300-012, PAGE 5, FIG 3. PERFORMED HFEC IAW NTM 51-10-08, WITH CRACK INDICATION LOCATED FR 68 FLANGE RADIUS TO INTERCOSTAL ATTACHMENT. TRIMMED OUT FLANGE OF FRAME 51-27-11 FIG 002, MEASURED THICKNESS OF FRAME WEB & CAPS AFTER TRIMMING OUT FLANGE NTM 51-10-04 AND 51-10-06, CRACK WAS NOT COMPLETELY REMOVED. PERFORMED ROTO TEST INSP NTM 51-10-01-250-802 AT FRAME WEB HOLES NEAR CRACK, INTERCOSTAL HOLES WITH FRAME FLANGE ATTACHMENT NOT REAMED. PERFORMED HOLE CENTERED IN MIDDLE OF CRACK, LENGTH 0.2841IN IS BTWN 0.2831/0.2858IN, PERFORMED ROTO TEST INSP NTM 51-10-01-250-802. MEASURED DISTANCE BETWEEN PERFORMED HOLE AND EXISTING ATTACHMENT TO HOLE CENTER REF FIG 004. DISTANCE E=0.887IN, D=0.850IN, C=1.003IN, DISTANCE IS GREATER TH AN 0.441 SRM 53-41-12-300-012 PG6 FIG 04. MEASURED DISTANCE BETW EEN PERFORMED HOLE AND EXISTING ATTACHMENT TO DOOR FRAME