As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING LT OTBD AILERON THERMOGRAFIC INSPECTION WAS NOTICED ONE POINT OF MOISTURE INGRESS ABOUT 25 INCHES FROM INBOARD EDGE LOWER SURFACE, ON A PREVIOUS REPAIR, WS 934.2 DAMAGE B# UPGRADE THE ATTRIBUTES TO MAJOR, PERFORMED THE SFR AND QC CHECK. ALL THE STEPS OF THE EC/RA 5760-01129 WERE ACCOMPLISHED WITHOUT DEVIATION RII - NO FURTHER ACTION, LP CLEARED.