What was found
INSPECTION FOUND A .5 INCH CRACK IN FLOORBEAM WEB AT STA 665, BBL 0. THE AREA WAS REPAIRED IAW EA 5710-01322, SRM 51-30-09 AND SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .5 INCH CRACK IN FLOORBEAM WEB AT STA 665, BBL 0. THE AREA WAS REPAIRED IAW EA 5710-01322, SRM 51-30-09 AND SRM 51-30-02.