As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION FOUND LT KEEL BEAM FAYING FLANGE FROM BS 663 TO 727 GALLED ON LOWER SURFACE AND WORN AROUND FASTENER HOLES ON UPPER SURFACE. EXISTING HOLES WERE OVERSIZED AND 3 EACH PRESS FIT BUSHINGS WERE INSTALLED. A REPAIR STRAP WAS FABRICATED AND INSTALLED. ALL WORK WAS PERFORMED IAW SRM 51-10-2, 51-30-2, ECRA 5310-03324, AND REO 02234.