What was found
INSPECTION FOUND A DENT WITH BONDING MATERIAL REPAIR ERODED IN NR 5 SLAT LEADING EDGE. A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 57-50-3, FIGURE 1, REPAIR 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A DENT WITH BONDING MATERIAL REPAIR ERODED IN NR 5 SLAT LEADING EDGE. A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 57-50-3, FIGURE 1, REPAIR 1.