What was found
INSPECTION FOUND FLOORBOARD SUPPORT CORRODED AT STA 200, RBL 10 TO RBL 44. THE FLOOR SUPPORT WAS REMOVED. A NEW SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBOARD SUPPORT CORRODED AT STA 200, RBL 10 TO RBL 44. THE FLOOR SUPPORT WAS REMOVED. A NEW SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 51-10-3.