What was found
INSPECTION FOUND FLOORBEAM CORRODED AT STA 947.5, LBL 3 TO 8. THE CORRODED AREA WAS CUT OUT AND A REPAIR WAS INSTALLED IAW SRM 53-00-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBEAM CORRODED AT STA 947.5, LBL 3 TO 8. THE CORRODED AREA WAS CUT OUT AND A REPAIR WAS INSTALLED IAW SRM 53-00-51.