What was found
INSPECTION FOUND AISLE EMERGENCY LIGHTING INOPERATIVE FROM ROWS 15 ABC TO 25 ABC. MAINTENANCE FOUND A BROKEN WIRE. THE WIRE WAS REPAIRED AND THE LIGHTS WERE TESTED IAW MM 33-51-00, PAGES 501 AND 503.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND AISLE EMERGENCY LIGHTING INOPERATIVE FROM ROWS 15 ABC TO 25 ABC. MAINTENANCE FOUND A BROKEN WIRE. THE WIRE WAS REPAIRED AND THE LIGHTS WERE TESTED IAW MM 33-51-00, PAGES 501 AND 503.