What was found
INSPECTION FOUND A .5 INCH CRACK IN AFT CARGO DOOR BEAM NR 3 FORWARD END FITTING. A NEW FITTING WAS INSTALLED IAW SRM 51-30-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .5 INCH CRACK IN AFT CARGO DOOR BEAM NR 3 FORWARD END FITTING. A NEW FITTING WAS INSTALLED IAW SRM 51-30-0.