What was found
INSPECTION FOUND FLOOR SUPPORT CORRODED AT BS 1280, LBL 11 TO RBL 11. THE FLOOR SUPPORT WAS REPLACED IAW SRM 51-10-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOOR SUPPORT CORRODED AT BS 1280, LBL 11 TO RBL 11. THE FLOOR SUPPORT WAS REPLACED IAW SRM 51-10-01.