What was found
INSPECTION FOUND A .75 INCH CRACK IN FRAME WEB AT STRINGER 24R AND A .75 INCH CRACK WAS FOUND IN FRAME WEB AT STRINGER 24L, BS 800. THE WEBS WERE REPAIRED IAW SRM 53-10-04, FIGURE 84.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .75 INCH CRACK IN FRAME WEB AT STRINGER 24R AND A .75 INCH CRACK WAS FOUND IN FRAME WEB AT STRINGER 24L, BS 800. THE WEBS WERE REPAIRED IAW SRM 53-10-04, FIGURE 84.