What was found
INSPECTION FOUND FORWARD CARGO BAY FLOOR SUPPORT TRACK CORRODED AT BS 640, STRINGER 28L. A FLOOR SUPPORT TRACK WAS FABRICATED AND INSTALLED IAW SRM 53-10-2, FIGURE 8, SRM 51-10-6, AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FORWARD CARGO BAY FLOOR SUPPORT TRACK CORRODED AT BS 640, STRINGER 28L. A FLOOR SUPPORT TRACK WAS FABRICATED AND INSTALLED IAW SRM 53-10-2, FIGURE 8, SRM 51-10-6, AND 51-30-2.