What was found
INSPECTION FOUND TWO 8 INCH CRACKS IN FORWARD CARGO PIT FLOOR SUPPORT AT STA 460, RBL 14. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-30-2 AND 51-40-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND TWO 8 INCH CRACKS IN FORWARD CARGO PIT FLOOR SUPPORT AT STA 460, RBL 14. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-30-2 AND 51-40-4.